AC VOLTS TRUE RMS 200/600 V

Fits Lynx, Leopard & Tiger 320 Series

Voltage Input.

Differential Voltage Divider.

Safe operation for connection to high voltages.

Header.

Selectable 200 V or 600 V input range.

Texmate Proprietary Designed

RMS-to-DC Convertor.

High accuracy, extremely linear.

Span Potentiometer.

Fine full scale adjustment.

State-of-the-Art

Electromagnetic Noise Suppression.

Circuitry ensures signal integrity even in harsh EMC environments.

Interface to Texmate's full range of modular panel meters.

True RMS voltage measurements for the AC power industry.

The IA06 true RMS input module provides unprecedented linearity over a choice of 200 or 600 volt RMS ranges utilizing the Texmate designed RMS-to-DC convertor circuit block. True differential input and high input impedance 2M improved RFI/EMI rejection and protection at high input voltages. High linearity means simple system calibration.

Input Module

Order Code Suffix

IA06

Hardware Module Specifications

200 V or 600 V RMS, header selectable 0.02 % linearity over full scale.

0 to 6 KHz, independent of input voltage.

1 mV RMS over full scale input.

Some Relevant Operating System Features

IA06 Data Sheet (NZ326)

Texmate, Inc. Tel. (760) 598-9899 www.texmate.com

Page 1

Connector Pinouts

Figure 1 IA06 Input Module Component La yout

Description

The AC volts true RMS input module is a universal module designed to function with the Lynx, Leopard, and Tiger range of indicators, meter relays, and programmable meter controllers (PMCs). Commonly used in the 0 to 200 V range, a 0 to 200/600 V range header provides the option to go to a higher v oltage.

The IA06 has a diff erential input with common mode filter ing and a v oltage divider to atten uate the high input v oltage to safe levels.

Zero input voltage produces a 0 output signal, meaning no z ero adjustment is necessar y.

Tiger Controllers and Leopard Meter Relays The Tiger and Leopard r ange use inter nal software functions to calibr ate the span. However, it may be necessar y to adjust the sp an potentiometer to bring the maximum input signal within the full scale r ange of the instrument.

When the input signal is be yond the full scale r ange of a Tiger controller, the display flashes [OVER]. When the input signal is be yond the full scale, the top range of a Leopard meter segment of each digit of the displa y flashes.

Figure 2 Span Potentiometer Adjustment

Turn the 15 tur n span potentiometer counter-clockwise to decrease the signal until a reading appears on the display (See Figure 2). Now calibrate the instr ument using the softw are calibration method f or y our instr ument.

Figure 3 Span Pot

Lynx Indicators

The span potentiometer is the only means of calibr ating Lynx indicators. When the input signal is beyond the full scale range of a Lynx indicator, a 1 is displayed in the most significant digit

(MSD) with all other digits b lank. Turn the 15 tur n span potentiometer counter-clockwise to decrease the signal until a reading appears on the display (See Figure 2).

Span Potentiometer (Pot)

The 15 tur n span potentiometer is located on the r side of the input module (when vie wed from the rear of the meter). Typical adjustment is 20% of the input signal r (See Figure 3).

ight-hand

ange

Tel: 1-760-598-9899 USA 1-800-839-6283 Thats 1-800-TEXMATE

Page 2

Texmate, Inc. Tel. (760) 598-9899 www.texmate.com

IA06 Data Sheet (NZ326)

About TexMate

Texmate is an American manufacturer of high durability industrial grade panel meters, bar graphs, and transducers. Texmate's meters are frequently equipped with relays and various signal outputs for industrial automation applications and are known for their extremely long service life.